cadence 各种错误集合

CADENCE 名称过长

#1   ERROR(SPMHNI-176): Device library error detected.

ERROR(SPMHNI-164): Problems with device 'TP2824C_TQFP40P1600X1600X160-12'. JEDEC_TYPE property 'TQFP40P1600X1600X160-128-TP2824C' is illegal: 'Package name is too long.'.

ERROR(SPMHNI-170): Device 'TP2824C_TQFP40P1600X1600X160-12' has library errors. Unable to transfer to Allegro.

capture:

allegro:


提示找不到封装,实际上库路径又是有的

WARNING(SPMHNI-194): Symbol 'TQFP40P1600X1600X160-128-TP2824C' used by RefDes U35 for device 'TP2824C_TQFP40P1600X1600X160-12' not found in PSMPATH or must be "dbdoctor"ed.

原因:封装是复制过来,只有dra,没有生产psm文件,重新另存为一次即可自动生成.


导出网表报PSTXNET.DAT语法错误

Could not create new pin inst: xxxx .
实际上是因为设计symbol封装时,pin name 末尾有空格,通常是由excel导入引脚编号、引脚名称时复制datasheet不小心复制进来的。
ctrl+insert 复制
shift+insert 粘贴

#allegro #cadence #orcad